CPM Overview

What is conventional ptychography?

In conventional ptychography (CPM), a coherent probe beam is scanned across a sample so that neighbouring illuminated areas overlap. At each scan position a camera records the diffraction pattern, which holds only the intensity. From these intensities, an iterative algorithm recovers both the complex object (amplitude and phase) and the probe.

flowchart LR
    probe[Probe] --> sample["Object patch<br/>at a scan position"]
    sample -->|exit wave| prop["Propagate<br/>(e.g. Fraunhofer)"]
    prop --> cam["Camera records<br/>the intensity only"]
\[ \psi_j = P\,O_j, \qquad I_j = \left|\mathcal{F}\{\psi_j\}\right|^2 \]

where \(P\) is the probe, \(O_j\) the object patch at scan position \(j\), \(\psi_j\) the exit wave, \(\mathcal{F}\) the propagation to the detector (a Fourier transform for Fraunhofer) and \(I_j\) the measured intensity.

Data flow

flowchart TD
    file[(HDF5 file)] --> exp["ExperimentalData<br/>diffraction patterns, geometry, scan positions"]
    exp --> rec["Reconstruction<br/>object, probe, positions"]
    params[Params] --> eng
    rec --> eng["Engine.reconstruct()<br/>ePIE, mPIE, mqNewton, ..."]
    eng -.->|updates| rec
    eng -.-> mon["Monitor<br/>live object, probe, error"]
    rec -->|"saveResults()"| out[(result.hdf5)]

Step-by-step reconstruction workflow

1. Load experimental data

ExperimentalData loads the diffraction patterns and the geometry from an HDF5 file. The required fields are ptychogram (diffraction intensities), wavelength, encoder (scan positions), dxd (detector pixel size) and zo (sample-to-detector distance).

See Data Format for the full HDF5 specification.

2. Initialize reconstruction state

A Reconstruction is created from the experimental data. It computes the coordinate grids, and initializeObjectProbe() creates the initial guesses:

  • Object: the complex transmission function of the sample
  • Probe: the complex illumination at the sample plane

The initial guess is set by reconstruction.initialObject and reconstruction.initialProbe:

Type Description
"circ" Circular aperture with random noise
"circ_smooth" Smoothed circular aperture
"ones" All-ones array with random noise
"rand" Fully random
"gaussian" Gaussian
"upsampled" Upsampled from the diffraction patterns (FPM object)

CPM uses "circ" for the probe and "ones" for the object by default.

3. Configure parameters

Params holds the settings shared by all engines: propagator type, constraint switches, regularization, position order and more. See the Parameter Reference for all options.

4. Choose and configure an engine

An engine implements one reconstruction algorithm. All engines share the same interface:

engine = Engines.mPIE(reconstruction, experimentalData, params, monitor)
engine.numIterations = 50
engine.reconstruct()

See Engines for the full list and which one to pick.

5. Iterate

engine.reconstruct() loops over the iterations, and in each iteration over the scan positions:

flowchart LR
    a["Object patch<br/>at position j"] --> b["Exit wave<br/>probe × patch"]
    b --> c["Propagate<br/>to detector"]
    c --> d["Replace amplitude<br/>with the measured one,<br/>keep phase"]
    d --> e["Propagate<br/>back"]
    e --> f["Update object<br/>and probe"]
    f -->|next position| a

The measured amplitude is \(\sqrt{I_j}\); the phase of the propagated exit wave is kept.

After each iteration, applyConstraints applies the Params switches (regularization, orthogonalization, corrections), and the Monitor updates its plots.

6. Save results

reconstruction.saveResults("result.hdf5")

Array layout

The object and probe are 6D arrays of shape (nlambda, nosm, npsm, nslice, N, N), with N = No for the object and N = Np for the probe. Singleton axes are kept:

Axis Default Meaning
nlambda 1 Number of wavelengths (polychromatic reconstruction)
nosm 1 Object state mixture (incoherent object modes)
npsm 1 Probe state mixture (incoherent probe modes, partial coherence)
nslice 1 Depth slices (multislice, for thick samples)
No, Np from the data Frame size in pixels

Set the first four on the Reconstruction before initializeObjectProbe() to reconstruct several wavelengths, modes or slices.

Note

Polychromatic reconstruction needs spectralDensity in the experimental data. Multislice reconstruction needs nslice > 1 and the e3PIE engine; see example 05.

Key concepts

Term Description
Object Complex transmission function of the sample
Probe Complex illumination at the sample plane
Ptychogram Stack of 2D diffraction intensities, one per scan position
Encoder / scan positions Physical (x, y) positions where the probe illuminates the sample
Exit surface wave (ESW) Product of probe and object patch: the field right behind the sample
Propagator How the wave is propagated between the sample and the detector
Intensity constraint Replace the computed amplitude with the measured one and keep the phase